JewelryDream.com Home
Home Your Account Wish List Customer Service Contact Us Search JewelryDream.comSearch
You have 0 item(s) in your Shopping CartShopping Cart
By Price RangeBy GemstoneEarringsNecklaces & PendantsRingsBracelets
Search  
  Browse By Categories

By Price Range
By Gemstone
Earrings
Necklaces & Pendants
Rings
Bracelets

  Browse By Expanding the Tree


  Browse By Category


JewelryDream.com Security

We use secure server technology (SSL) to keep your personal information - including your billing and account information - as secure as possible.

Once your information is stored on our database, we have database security technologies and procedures in place to protect it from access by unauthorized personnel.

Security Practices
Technology Used Description Success Rate
SSL - 128 Bit Encryption The most powerfull web site security system available to all commercial web sites.  The Secure Socket Layer server based technology certificate purchased by us from one of the most trusted SSL Certificate authorities verifies us as a valid site and provides a secure link to your connection.  We employ SSL to automatically encrypt your connection to us when you enter any page on our site deemed private and personal by us.  During a connection protected by SSL, you will see a LOCKED Pad-Lock image in one of the small panes located in the bottom right corner of your browser window if you are using Microsoft's Internet Explorer.  There are other indicators if you are using an alternate browser.  You can also check a web page privacy state by going to the File menu option usually located near the upper left corner of your browser window and selecting the properties option.  If a web page is secure under the connection section you will see SSL 3.0, RC4 with 128 bit encryption (High); RSA with 1024 bit exchange. 100%
Datacenter

The Datacenter is the location where your information is processed and stored.  Below is some very detailed information describing our datacenter.

1      FACILITY

  • Concrete Tilt-Up Construction
  • 24 inch raised floor
  • All racks / cabinets are seismically braced and bolted directly to the concrete flooring
  • Dimax – Building Management / Alarm Monitoring System
  • Power and data cables are run perpendicular from each other to minimize any electrical field interaction
  • Janitorial service is bonded, insured and licensed

2      SECURITY

  • 7/16 inch thick steel sheeting around the front door and within the front reception area
  • 2 level, man-trap, security access – before actually being able to enter the raised floor area
  • 256+ - fixed positioned, security cameras
  • All camera footage is recorded and held for a minimum of 30 days
  • Level 5 bullet-resistant walls / glass (Kevlar Lined walls) in the front entry, lobby, guard station, and shipping and receiving areas
  • 24 x 7 x 365 on-site security guards
  • Security service is bonded
  • No signage on building

3      AIR CONDITIONING

  • Data Center temperature maintained at 72 degrees +/- 2 degrees
  • Thermostats / Humidistats are located around the building on the walls, posts and ceilings
  • 16 – 135 Ton air conditioners N+6 – all 16 are running continuously w/redundant capacity
  •   6 – 135 Ton air conditioners support redundant capacity
  •   2 – 30 ton air-conditioners independently support NOC and NODE
  • Air handlers are located on the roof (roof access is restricted and monitored).
  • Supply air temperature entering the IDC averages 55 – 62% varying with load conditions
  • Ring duct in ceiling allows us to add diffusers (vents) where needed to provide additional air flow
  • 2 – 125 Ton A/C Units, and 1 – 70 Ton unit is dedicated to UPS Room

4      POWER

  • Pager notification service with an Independent System Operator (ISO) to monitor utility power Stage Alerts and rolling black outs
  • 6 main electrical distribution buses
  • 24 MGE UPS’s  
  • 10 Caterpillar 2000KW (2.0MW) generators
  • Each generator has 3,000 gals of diesel fuel – enough to power it for 22 hours at full load
  • 4 – 12,000 gal. Diesel Fuel storage convault tanks (in addition to the primary fuel tanks) provide enough fuel to run generators continuously for 72 hours at full load
  • UPS batteries support data center load until automatic transfer to generator is completed
  • 50 power management modules (PMM’s) with 168 – 20 amp power circuits from each 165KVA power distribution unit (PDU); customized circuits provided as needed;
  • Power is served to the PDUs via 2 separate independent UPS power sources
  • Each PDU has it’s own Automatic Static Transfer Switch which can switch the power to the alternate source within 4 milliseconds
  • Contracts with local fuel companies to provide additional on-site fuel, once generators are started

5      FIRE SUPPRESSION

  • VESDA – Very Early Smoke Detection and Alarm system; small white ‘air sampling tubes’ draw air into chambers, where lasers analyze the air for smoke content
  • Clean-Gas hand-held fire extinguishers are through-out the building
  • Fire station located approximate 600 feet from the data center.
  • Heat detectors (140 degree) and Smoke detectors are located on the ceilings around the building

6      NETWORK/BANDWIDTH

  • Redundant OC48s
  • X – 4 inch conduits for telco fiber leading to the street
  • Multiple redundant network paths
  • All network operators certified internet systems engineers
100%
 

Home | Contact Us | Affiliates | Return Policy | Privacy Policy | Security Policy | Site Map | Copyright© 2005. All Rights Reserved.